Scopul nostru este sprijinirea şi promovarea cercetării ştiinţifice şi facilitarea comunicării între cercetătorii români din întreaga lume.
General Manager / Senior Scientist, Bucharest, .
E-mail: trimite un mesaj.
Pagina web a instituţiei: http://www.accent.ro
Pagina web personala: http://www.accent.ro/M_Iovea_CV.pdf
Nascut(a) in: 1954
Interese: NDT, x-ray tomography, x-ray radioscopy, dual/multi-energy, tomogram reconstruction, X-ray materials identification, data and image analysis, LabView data acquistion and analysis, programs development
Details:
< July 2000 - Present >
General Manager and Senior Research Scientist with ACCENT PRO 2000 S.R.L Company (please visit www.accent.ro), Bucharest, Romania
Activities:
Design and development of X-ray Tomography/radioscopy equipment for:
industrial NDT, security (explosives detection),sedimentary cores and minerals analysis;
Baggage control detection algorithms studies by X-Ray dual-energy technique in tomography and radioscopy.
R&D Management and Consulting.
< Feb.1999 - May 2000 >
Postdoctoral fellow with The Johns Hopkins University, Department of Physics and Astronomy, Plasma Spectroscopy Group of Baltimore, Maryland, USA;
Long-term Research scientist visitor at Princeton Plasma Physics Laboratory, Princeton University, New Jersey
Activities:
R&D of tomographic systems dedicated to Soft X-Ray plasma diagnostics for NSTX Tokamak;
Designing and building data acquisition and software packages for tomographic systems.
< 1991 - 1999 >
Senior Scientist, Head of the "Computerized Control and Non-Destructive Testing Laboratory" and Head of a NDT Nuclear Unit, at the R&D Institute for Electrical Engineering - ICPE S.A., Bucharest.
Activities:
R&D oriented to new-product and new computerized technique development (for more details please visit the Lab Site http://www.icpe.ro/lab/comp-ndt/) in the following domains:
2D and 3D Industrial gamma-ray Computerized Tomography;
Immersion Ultrasound scanner with focalized transducers;
Multi-channel Acoustic Emission equipment;
Vibration Monitoring Systems;
High-accuracy density measurement;
Studies and experiments in Electrical Impedance Tomography;
Stands for complex electrical tests and measurements for electrical motors and tools equipped with electrical motors;
Magnetic-powder brakes and eddy current brakes design;
Laboratory Department Manager; representative and dealer activity.
< 1990 - 1991 >
Scientific Director with R&D Institute for Electrical Engineering (ICPE S.A.), Bucharest
Activities:
Building and implementing new technical and economical algorithm for the R&D departments development;
Scientific management for following domains/laboratories: Non-conventional energy (solar, wind, etc.), Non Destructive Testing, R&D for Electrical Materials, Accelerating Aging tests, Electrical Technologies, Quality Assurance in Electrical Domain, Superconductivity, Medical Equipment, Microwave, Tests of equipment destined for Nuclear Power Plants;
< 1984 - 1990 >
Research Scientist with R&D Institute for Electrical Engineering - ICPE S.A., Bucharest.
Activities:
Development of techniques and instrumentation for monitoring electrical equipment behavior during the "Seismic Test" and "Loss of Cooling Accident Test" for Nuclear Power Plants qualification.
< 1982 - 1984 >
Research Scientist with the Institute for Nuclear Reactors - IRNE, Pitesti - Romania.
Activities:
Participating at the development of dedicated stand for nuclear fuel test and analysis.
Publicații selectate:
* M. Iovea, G. Mateiasi, O.G. Duliu, M. Neagu, M. Mangu, COMBINED X-RAY DUAL-ENERGY RADIOSCOPY AND TOMOGRAPHY ANALYSIS FOR EXPLOSIVES DETECTION, Materials Evaluation, vol 67, No.12, 2009.
* Mihai Iovea, Marian Neagu, Octavian G. Duliu,Gheorghe Oaie, Stefan Szobotka, Gabriela Mateiasi, A DEDICATED ON-BOARD DUAL-ENERGY COMPUTER TOMOGRAPH, Springer, Journal of Nondestructive Evaluation, Volume 30, Issue 3, 2011.
* V.A. Soukhanovskii, D. Stutman, M. Iovea, M. Finkenthal, H.W. Moos;, 18. MULTILAYER MIRROR AND FOIL FILTER AXUV DIODE ARRAYS ON CDX-U SPHERICAL TORUS, Review of Scientific Instruments, 72 #1, 2001.
* M Iovea, A Vamvakoussis, G Mateiasi, V Georgiou, G Samoilis, M Neagu, 17. DEVELOPMENT OF DIGITAL RADIOGRAPHY CONTROL AND INDUSTRIAL TOMOGRAPHY FOR NON-DESTRUCTIVE TESTING IN GREECE, INSIGHT, September 2001 Vol 43 No 9, 2001.
* M. IOVEA, G. OAIE, C. RICMAN, G. MATEIASI, M. NEAGU, S. SZOBOTKA, O.G. DULIU, DUAL ENERGY X-RAY COMPUTER AXIAL TOMOGRAPHY AND DIGITAL RADIOGRAPHY INVESTIGATION OF CORES AND OTHER OBJECTS OF GEOLOGICAL INTEREST, Engineering Geology, 103, 2008.
* M.Iovea, O. Duliu, et all, 4. DUAL ENERGY COMPUTED TOMOGRAPHY AND DIGITAL RADIOGRAPHY INVESTIGATION OF ORGANIC AND INORGANIC MATERIALS, Proceedings of the 9th European Conference on NDT - ECNDT Berlin September 2006 – CD-ROM, 2006.
* M. Iovea, G. Mateiasi, M. Neagu, 3. PURE TRANSLATIONAL TOMOGRAPHY - A NON-ROTATIONAL APROACH FOR TOMOGRAPHIC RECONSTRUCTION, Proceedings of the 9th European Conference on NDT - ECNDT Berlin September 2006 – CD-ROM, ECNDT 2006 - Tu.1.4.2, 2006.
* M. Iovea, M. Neagu, O. Duliu, G. Mateiasi, High accuracy X-ray dual energy experiments and non-rotational tomography algorithm for luggage control, International Symposium on Digital Industrial Radiology and Computed Tomography (DIR 2007) held in June 2007 in Lyon France, 2007.
* M. Iovea, M. Neagu, O. Duliu, G. Oaie, G. Mateiasi, On-ship drilling cores dedicated dual energy X-ray tomography/radioscopy equipment, Symposium on Digital Industrial Radiology and Computed Tomography (DIR 2007) held in June 2007 in Lyon France, 2007.