Scopul nostru este sprijinirea şi promovarea cercetării ştiinţifice şi facilitarea comunicării între cercetătorii români din întreaga lume.
Domenii publicaţii > Chimie + Tipuri publicaţii > Articol în revistã ştiinţificã
Autori: D. Oancea, D. Razus, V. Munteanu, I. Cojocea
Editorial: Journal of Loss Prevention in the Process Industries, 16(5), p.353-361, 2003.
Rezumat:
The original break spark test apparatus for intrinsically safe circuits was modified to allow the measurements of minimum ignition currents (MICs) at different initial pressures between 20 and 120 kPa. The MICs of different propylene/air mixtures at ambient temperature and at both atmospheric and sub-atmospheric pressures were measured. The corresponding minimum ignition energies (MIEs) using break sparks were calculated and compared with those derived from MIE/quenching distance correlations using high voltage sparks between flanged electrodes.
Cuvinte cheie: Flammable gas mixtures, Intrinsically safe circuit, Break sparks, Inductive–capacitive sparks, Minimum ignition current, Quenching distance, Minimum ignition energy, Methane, Propylene