Autori: C. Cojocaru et al
Editorial: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Volume 531, Issue 3, p.481-514, 2004.
Rezumat:
A full azimuthal eta-wedge of the ATLAS liquid argon end-cap calorimeter has been exposed to beams of electrons, muons and pions in the energy range View the MathML source at the CERN SPS. The angular region studied corresponds to the ATLAS impact position around the pseudorapidity interval 1.6<|eta|<1.8. The beam test setup is described. A detailed study of the performance is given as well as the related intercalibration constants obtained. Following the ATLAS hadronic calibration proposal, a first study of the hadron calibration using a weighting ansatz is presented. The results are compared to predictions from Monte Carlo simulations, based on GEANT 3 and GEANT 4 models.
Cuvinte cheie: Liquid Argon calorimeter; High energy physics detector; Calorimeter; ATLAS detector