Scopul nostru este sprijinirea şi promovarea cercetării ştiinţifice şi facilitarea comunicării între cercetătorii români din întreaga lume.
Domenii publicaţii > Stiinte ingineresti + Tipuri publicaţii > Articol în revistã ştiinţificã
Autori: Adriana Valcu
Editorial: SPRINGER, SPRINGER , MAPAN Journal, 27, p.183, 2012.
Rezumat:
This paper reports the results of measurements performed on five standard weights of class F2, by several metrology laboratories throughout Romania. The comparison began in 2009 and concluded in 2010. Mass Laboratory of National Institute of Metrology (INM) acted as pilot laboratory (PL) and reference laboratory (RL) for the programme. Five standard weights of class F2 (nominal values: 5 kg, 1 kg, 200 g, 100 g and 10 g) were sent to the participants. The laboratory’s results are presented for each weight, along with the associated uncertainty and the normalized errors of each laboratory, with respect to the INM. The results obtained by the participating laboratories in this comparison can be used to validate the measurement capabilities (in the calibration of weights)claimed/approved under the quality management systems.
Cuvinte cheie: Interlaboratory comparison - Normalized error - Pilot laboratory - Reference laboratory